Technetium TC 99M Pyrophosphate
  • Professionals
  • FDA PI

Technetium TC 99M Pyrophosphate

Dosage form: injection
Drug class:Radiologic conjugating agents

Medically reviewed by Drugs.com. Last updated on Jan 24, 2022.

Kit for the Preparation of Technetium TC 99M Pyrophosphate Injection

Rx Only.

Diagnostic–For Intravenous Use

Technetium TC 99M Pyrophosphate Description

TechneScan™ PYP™ (kit for the preparation of Technetium TC 99M Pyrophosphate Injection) is a sterile, non-pyrogenic, diagnostic radiopharmaceutical suitable for intravenous administration after reconstitution with sterile sodium pertechnetate Tc 99m injection or sterile 0.9% sodium chloride injection.

Each 10 milliliter reaction vial contains 11.9 milligrams sodium pyrophosphate, 3.2 milligrams (minimum) stannous chloride (SnCl2•2H2O) and 4.4 milligrams (maximum) total tin expressed as stannous chloride (SnCl2•2H2O) in lyophilized form under an atmosphere of nitrogen. Prior to lyophilization the pH is adjusted with hydrochloric acid. The pH of the reconstituted drug is between 4.5 and 7.5. No bacteriostatic preservative is present.

The precise structures of the stannous-pyrophosphate and technetium-stannous-pyrophosphate complexes are not known at this time.

PHYSICAL CHARACTERISTICS

Technetium Tc 99m decays by isomeric transition with a physical half-life of 6.02 hours.1 The principal photon that is useful for detection and imaging is listed in Table 1.

Table 1. Principal Radiation Emission Data1
Radiation Mean Percent/Disintegration Energy (keV)
Gamma-2 89.07 140.5

The specific gamma ray constant for technetium Tc 99m is 0.78 R/mCi-hr at 1 cm. The first half-value thickness of lead (Pb) for technetium Tc 99m is 0.017 cm. A range of values f...